ICP Example 1

More
5 years 3 months ago #270 by Naveen
ICP Example 1 was created by Naveen
Hello,

I am just starting with ICP and i had a few basic questions. I am trying to run example 1 from the folders and the output file gives a different plot than expected. I am not sure if i changed anything from the json file. I realized while comparing the results to the plot given in the manual that the results from phreeqc and HP1 are similar while ICP results dont match. I have attached an image of the plot from comsol and also the json file. Can someone please tell me which section of the code corresponds to the ICP part and what is making the ICP values differ ?

Any guidance is much appreciated.

Thanks
Naveen

Please Log in or Create an account to join the conversation.

More
4 years 11 months ago #274 by Alvaro Sainz
Replied by Alvaro Sainz on topic ICP Example 1
Hello Naveen,

We are sorry for the late response. The json file is right, the problem is the visualization on Comsol. The iCP results are shown in seconds while the HP1 and the PHREEQC are displayed in days. To change the units go to the “x-Axis Data” on the iCP results. Change to Expression, using t and changing the unit to days (please, see the attachment).


Best
Alvaro
Attachments:

Please Log in or Create an account to join the conversation.